The 278 atmospheric pressure transducer is designed for use in environmental applications that require excellent accuracy, fast dynamic response, and long-term stability and reliability. To withstand the environmental extremes typically found in Automated Weather Systems (AWS) applications, the Model 278 housing is constructed of stainless steel and polyester. A terminal strip is provided for connection to DCP’s signal/power supply connections, and a 1/8” Barbed fitting is used for pressure connection. The transducer’s footprint (3.6” x 2.4” x 1.0”) making it ideal for use as a new or drop-in replacement to existing configurations.
Specifications
Accuracy: ±0.5 hPa/mb @ +20°C (+68°F)
±1.0 hPa/mb @ 0° to +40°C (0 to +104°F)
±1.5 hPa/mb @ -20° to +50°C (-4°F to +122°F)
±2.0 hPa/mb @ -40° to +60°C (-40°F to +140°F)
Non-Linearity: ±0.4 mb
Hysteresis: ±0.05 mb
Non-Repeatability: ±0.03 mb
Resolution: 0.01 mb
Long Term Stability: 0.1 mb/Yr
Warm-up: <1 sec. from Shutdown Mode (Warm-up shift <0.1 mb maximum)
Response Time: <100mSec
Electrical Data
Electrical Circuit: 3 or 4 Wire
Excitation: 9.5 to 28 VDC
Output: 0 to 2.5VDC; 0 to 5 VDC
Output Impedance: <10 Ohms
Output Noise: <50 Microvolts
Current Consumption: 3 mA Nominal (Operating Mode) 1 µA (Sleep Mode)
Pressure Media:Non-condensing air or gas.
Environmental Data
Operating Temperature: -40° to +60°C (-40°F to +140°F)
Storage Temperature: °F (°C) -60° to +120°C (-76°F to +248°F)
Physical Description
Case: Stainless Steel and Polyester
Pressure Fitting: 1/8” (ID dia.) Barbed Fitting
Electrical Connection: 5-Pin Terminal Block
Dimensions: 3.6” x 2.4” x 1.0”
Weight: (approx.) 4.8 oz (135g)
Pressure Fitting: 1/8" Tube Fitting
Pressure Media: Non-condensing air or gas compatible with stainless steel, alumina ceramics,
gold and elastomer.